T8 Sterilization Lamp Disinfection Lamp Bracket High Boron UVC Sterilization Anti-Mite Disinfection Fluorescent Fixture
Packaging information: |
|
---|
T8 series disinfection lamp
wattage | glass material |
lamp Size (Length x diameter) |
bracket size (Length x width x height) |
ultraviolet wavelength | rated life | recommended sterilization area |
10W | high Boron/quartz | 331x26mm | 358x32x50mm | 189nm/254nm | ... | 6-10 square meters |
15W | high Boron/quartz | 435x26mm | 462x32x50mm | 189nm/254nm | ... | 10-15 square meters |
20W | high Boron/quartz | 589x26mm | 616x32x50mm | 189nm/254nm | ... | 15-20 square meters |
30W | high Boron/quartz | 896x16mm | 923x32x50mm | 189nm/254nm | ... | 20-30 square meters |
36W/40W | high Boron/quartz | 1200x16mm | 1228x32x50mm | 189nm/254nm | ... |
25-40 square meters |
1) T5 series is recommended for requirements below 35cm, and T8 series is recommended for requirements above 35cm;
2)T5 series and new T8 series lamps can be connected in series or in parallel;
3) the rated life cannot be directly equal to the actual life, and the actual service life varies according to the room temperature of the actual use environment;
4) High Boron material or quartz material can be selected in the glass material. The prices of the two materials will vary. Please communicate with our customer service before purchasing;
5) the lamp is an ozone-containing lamp. By default, all the lamps shipped by our company are ozone-containing double disinfection lamp.
Key notes:
european standard and international standard are marked as 10W, 15W, 18W, 30W and 36W respectively.
Our Chinese standard is marked as 10W, 15W, 20W, 30W and 40W.
North America (USA and Canada) and South America are marked as 10W, 15W, 17W, 25W and 32W or more
the length of the corresponding lamp tube is normal, except for customized products.
● instructions
after lighting, the lamp tube emits light blue visible light, and at the same time, it is accompanied by high-intensity ultraviolet light that is invisible to the naked eye at 253.7nm. Because ultraviolet light will kill cells, therefore, when sterilizing ultraviolet rays, we should pay attention not to directly irradiate human skin, especially human eyes. Do not look directly at the lamp tube when ultraviolet rays sterilization lamp are lit. Because short-wave ultraviolet rays do not penetrate ordinary glass, wearing glasses can avoid eye damage. If you don't hurt yourself, the general situation is not serious. Just like being burned by sunlight, you can drop eye drops or human milk to help you recover. Leave the room or specific disinfection space quickly 10-30 seconds after lighting up to avoid damage!