Supply 5L Automatic Electronic Decocting Pot Multi-Function Ceramic Health Pot Electric Traditional Chinese Medicine Pot Pot Medicine Boiling Device
Packaging information: |
|
---|
............................................................................................................................................................................................................................................................................................................
Product features: (This product has ten features)
1. Fully automatic decoction, automatic control of the dosage, just a bowl of liquid medicine is left,
2. Anti-boiling overflow, large spout, smooth exhaust, excellent medicine
3. Fully automatic heat preservation, which can keep warm for five to eight hours without care
4. Special two levels of Fast and Slow fire can promote the precipitation of effective ingredients and Fry higher quality drugs. (Some models)
5. Multi-purpose, can be fried medicine, boiled water, stewed tonic, soup for health care
6. The core structure adopts high-tech temperature control and overheating protection system.
7. Do not charring when frying, save electricity and safety, and keep the liquid medicine
8. Elegant shape, made of Chinese porcelain art designed by a maestro, body refined with high temperature resistant ceramics, superior thermal shock resistance
9. Large capacity, high temperature resistance, durable.
10. This product has passed China mandatory 3C security certification.
Instructions for use:
1. Test
when you use it for several times, pour clean water into body first. The water level must be about 0.5cm higher than that of the heating element at the bottom of body, and then turn on the power supply. If you have a model with fast and slow gear function, set it to fast gear, at this time, electric kettle will be automatically heated to boiling until the water is evaporated to below the heating element, and the heating stop and jump insulation prompt (green light) will be automatically stopped. After the test is completed, the machine can work normally.
2. Pay attention to switching on the power supply
when switching on the power supply, the wire must be inserted into the machine first, and then the other end of the wire must be inserted into the socket. Do not insert the socket into the machine first, and improper operation will easily cause short circuit to touch the fire and burn the wire. When switching on the power supply, make sure that water is placed inside the body and the internal heating element is at least 1cm higher than the body.
3. How much medicine to put, how much water to put and how long to cook.
Usually 3 bowls of boiling 8 points is a good reference. According to the machine principle, the water level must be higher than the heating element, not more than 70% of the height of body (to prevent excessive water from overflowing), after the machine starts to work, it will automatically heat up. When the water evaporates below the heating element, it will start to stop working and be in the state of heat preservation. When the water is lower than the heating element, pour out about 1 bowl of water (depending on the density and consistency of different dregs). For example, if you cook mung bean medicine, it is granular, which occupies space and fills the bottom. At this time, the amount of liquid medicine will be very small. However, if the medicine you cook is coarse and big leaf-shaped, the bottom is actually not filled with much space, and the liquid medicine will come out. The more water is placed, the longer the brewing medicines will be, the higher the concentration of the drug will be, and vice versa. Normal brewing medicines time fast gear is 1-2 hours, slow gear is 3-6 hours, usually use fast gear frying, the machine will work automatically. In particular, if you need to slow down, please use slow-speed (usually very few).
4. Two pairs of medicine are boiled together, and one pair of medicine is boiled together.
If a customer wants to cook two medicines together and cook them into 2 bowls, in this case, the power is manually controlled, that is, when you see about 2 bowls of water left, the power is manually cut off, there are 3 bowls of water left, and 4 bowls of water are the same.
If a customer will immediately cook the second pair of medicine or recook the second pair of medicine when a pair of medicine is poured out, if Quench time is too short, it is easy to damage the heating original or thermostat. In this case, please try to cook the second pair of medicine after the temperature of body drops, especially when recooking auxiliary medicine, it takes Quench time longer because the original pot slag is very hot.
5. Precautions
do not place body in water for cleaning, which will cause the bottom to enter water and damage the circuit.
When inserting the wire, insert the wire into the machine first, and then insert the other end of the wire into the socket. Do not insert the socket into the machine first, which will easily lead to short circuit of the wire and fire.
If the machine is still working, it is possible that the heating element part of the machine is covered with residue, which affects the operation of the thermostat. If the test water (without residue) still exists, if there is a problem with the temperature control circuit of the machine, please contact the replacement.
★★Note:
→ pay attention to the consistency of power supply voltage and keep good contact;
→ it is strictly forbidden to empty the pot or not add water to power after charging;
→ it is strictly forbidden to add cold water at body high temperature (sudden cold and sudden heat will cause ceramic or glass objects to break);
→ body is ceramic body, should be handled gently, do not put it on the table with inclination greater than 5°C;
→ when the power is on, do not touch the child, and do not wipe it with a damp cloth, in case of outside;
→ do not soak or rinse the entire body in water to prevent circuit damage;
→ do not use hard objects to wash the heating body in the pot, and use stainless steel wire ball to wash its surface;
→ do not disassemble any electrical products privately. If necessary, they should be handed over to the common sense of circuits or the manufacturer's special warranty point for repair and maintenance.